Specifications
(TWD-EL-ONLINE)Online Measurement for Electrolyte Specific Gravity
Application: Solution monitoring in chemical battery factory, electrolytic polishing factories and electrolytic degreasing factories.
Principle: Referring to the standard of GB/T611, T2423, ISO 6353, and by adopting hydrostatics buoyancy method, Bernoulli principle of hydrodynamics to online monitor the specific gravity change of electrolyte, and then by applying Lagrange polynomial interpolation, the dynamic data of online electrolyte concentration can be converted, and then the charging degree of lead-acid battery can be determined.
With the special design of buffering device TP-30, it is fully consistent with the hydrostatic principle; the data tested will be more accurate.
Specifications:
Model: TWD-EL-ONLINE
S.G range: 0.0001 – 2.0000(glass weight)
Testing type: Specific Gravity (S.G), Baume (Bé), Concentration (C%)
S.G precision: 0.0001
Bé range: 0.1~80.0 Bé
C% range: 0.1%~100.0%
Standard Interface: RS-232
Functions:
1. The main-body of this device is placed on the easy-operation platform, and the main-body is equipped with sampling tank.
2. The testing liquid is in and out from the in-out hole on sampling tank, the liquid specific gravity will be showed automatically by according to the buoyancy changing of sensor ball in sampling tank.
3. Just by continuous actions, the charging degree of lead-acid battery can be determined according to the specific gravity change of the electrolyte.
4. Just by continuous actions, the online electrolyte specific gravity measurement and monitor can be finished, and then the dynamic data of online electrolyte concentration can be converted and showed.